Client Protection
Dedicated Support
Genuine Products
Dwyer CDT-2E44 | Carbon Dioxide Transmitter | Backplate
The Dwyer CDT-2E44 is a carbon dioxide transmitter with output Universal: 4-20 mA, 0-5 VDC or 0-10 VDC, electrical connection Backplate and mounting Wall mount (European housing). Dwyer lists by integrating temperature and CO2 readings into a single transmitter, you may reduce inventory and save time., uses Automatic Baseline Correction (ABC) to correct for sensor drift and requires little maintenance. and use a CO2 sensor that is low energy, repeatable, and dependable to cut down on operating expenses. among its features.
- Mounting: Wall mount (European housing)
- Accuracy: CO₂: ±40 ppm + 3% of reading (2000 PPM); Temperature: ±1°C at 25°C
- Approvals: CE
- Enclosure Rating: IP20
- Humidity: Limits: 0 to 85% RH (non-condensing)
- Maximum Operating Temperature: 32 to 122°F (0 to 50°C)
- Output: Universal: 4-20 mA, 0-5 VDC or 0-10 VDC
- Temperature Output: Yes (analog temperature output)
- Specifications
- Features
- Downloads
| Part Number | CDT-2E44 |
| Brand | Dwyer Instruments |
| Type | Carbon Dioxide/Temperature Transmitter |
| Accuracy | CO₂: ±40 ppm + 3% of reading (2000 PPM); Temperature: ±1 °C at 25 °C |
| Output | Universal: 4-20 mA, 0-5 VDC or 0-10 VDC |
| Range | CO₂: 0 to 2000 PPM Temperature: 32 to 122 °F (0 to 50 °C) |
| Response Time | 2 minutes for 90% step change |
| Approvals | CE |
| Maximum Operating Temperature | 32 to 122 °F (0 to 50 °C) |
| Power | 16-35 VDC or 19-28 VAC |
| Sensor Type | Single-beam, dual-wavelength NDIR (15-year life expectancy) |
| Display | None |
| Mounting | Wall mount (European housing) |
| Enclosure Rating | IP20 |
| Humidity | Limits: 0 to 85% RH (non-condensing) |
| Power Consumption | Average: 2 W Peak: 3.75 W |
| Temperature Output | Yes (analog temperature output) |
| Electrical Connection | Backplate |
- By integrating temperature and CO2 readings into a single transmitter, you may reduce inventory and save time.
- Uses Automatic Baseline Correction (ABC) to correct for sensor drift and requires little maintenance.
- Use a CO2 sensor that is low energy, repeatable, and dependable to cut down on operating expenses.
- Using a backplate electrical connection will simplify installation.
Other models in this series
Click a row to open that product.
Related Products
Dwyer CMS300-FC | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer CMS300-FC | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer CMS300 | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer CMS300 | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer GSTC-N-LCD-FC | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-LCD-FC | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-LCD | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-LCD | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer Instruments GSTC-N-FC | Nitrogen Dioxide transmitter with BACnet & Modbus® communication | Includes factory calibration certificate
Dwyer Instruments GSTC-N-FC | Nitrogen Dioxide transmitter with BACnet & Modbus® communication | Includes factory calibration certificate
Dwyer GSTC-N-D-FC | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-D-FC | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-D | Nitrogen Dioxide Duct Transmitter | 0-10 ppm NO2, BACnet/Modbus
Dwyer GSTC-N-D | Nitrogen Dioxide Duct Transmitter | 0-10 ppm NO2, BACnet/Modbus
Dwyer GSTC-N | Carbon Dioxide Transmitter | CO: 0 to 500 PPM NO₂: 10 PPM, Drift: <5% per year in air
Dwyer GSTC-N | Carbon Dioxide Transmitter | CO: 0 to 500 PPM NO₂: 10 PPM, Drift: <5% per year in air