Fluidwell F014 | Intrinsically Safe Flow rate Indicator / Totalizer | with pulse output, ambient -40°C to +70°C
The F014 is a local flow rate indicator / totalizer which displays the actual flow rate, total and accumulated total. A scaled pulse, related to the accumulated total is generated for re-transmitting the count on the display. Total can be reset to zero by pressing the CLEAR button twice. Typical use: Flow measurement where re-transmission of the totalizer function is required.
Key features
- Displays total and flow rate simultaneously and additional accumulated total.
- Large digit selection for flow rate or total.
- Selectable on-screen engineering units for total: ml, L, m³, GAL, USGAL, kg, lb, bbl or no unit.
- Scaled pulse output reflecting the accumulated total.
- Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
- Total - resettable: seven 17mm (0.67") digits.
- Accumulated total - not resettable: eleven 8mm (0.31") digits.
- Specifications
- Features
- Downloads
| Part Number | F014 |
| Brand | Fluidwell |
| Product Type | Flow rate Indicator / Totalizer |
| Enclosure / Area | Safe area / Intrinsically safe |
| Ambient Temperature | -40 °C to +70 °C (-40 to 158 °F) |
| Signal Inputs - Flowmeter Inputs | Pulse type inputs: Reed-switch, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal.; (0)4 – 20mA. |
| Supply - Power Supply | Long life Lithium battery.; 4 – 20mA, input Loop-powered.; 8 – 24V AC/DC.; 115 – 230V AC.; Basic: 8 - 30V DC. |
| Supply - Sensor Supply | 3.2, 8.2, 12, 24V DC. |
| Signal Outputs - Pulse Outputs | Function: Scaled pulse output according to accumulated total (e.g. one pulse every 3.25 gallons). Max. frequency: 500Hz. Adjustable pulse length from 1 msec. to 10 seconds.; Type: One passive NPN transistor, active PNP transistor or isolated electro-mechanical relay. |
| Hazardous Area - Intrinsically Safe | ATEX: Gas: II 1 G Ex ia IIC T4 Ga Dust: II 1 D Ex ia IIIC T200 100 °C Da; IECEx: Gas: Ex ia IIC T4 Ga Dust: Ex ia IIIC T200 100 °C Da; CSA: I.S. Class I/II/III, Div 1, Grp A...G, T4 Class I, Zone 0, AEx ia IIC T4 Ga Note: Extended aluminum enclosures not available with CSA/FM approval. |
- simultaneously shows the total, the flow rate, and any additional accumulated total.
- Large digit selection available for total or flow rate.
- Engineering units for flow rate that can be chosen on-screen include mL, L, m³, mg, g, kg, ton, GAL, bbl, lb, cf, REV, scf, Nm³, NL, P, or no unit at all. /sec, /min, /hour, or /day are the time units for flow rate.
- Engineering units for the total that can be chosen on the screen include kg, lb, bbl, GAL, USGAL, ml, L, and m³.
- Scaled pulse output with the sum accumulated reflected in it.
- Seven 17mm (0.67") or 8mm (0.31") numbers indicate the flow rate.
- Total: seven resettable digits measuring 17 mm (0.67").
- Total accumulated: eleven 8mm (0.31") non-resetable digits.
- distinct technical units for total and flow rate.
- Backlight made of LEDs with intensity control.
- In accordance with ATEX, IECEx, FM, and CSA C-US, intrinsic safety.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell F114 | Intrinsically Safe Ratio Monitor / Totalizer | with high / low alarms and analog outputs, ambient -40°C to +70°C
Fluidwell F114 | Intrinsically Safe Ratio Monitor / Totalizer | with high / low alarms and analog outputs, ambient -40°C to +70°C
Fluidwell F116 | Intrinsically Safe Differential / Sum Flow Computer | with Modbus communication, analog and pulse outputs, ambient -40°C to +70°C
Fluidwell F116 | Intrinsically Safe Differential / Sum Flow Computer | with Modbus communication, analog and pulse outputs, ambient -40°C to +70°C
Fluidwell E126-EG | Explosion proof Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EG | Explosion proof Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EL | Explosion proof Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EL | Explosion proof Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell F127 | Intrinsically Safe Differential Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell F127 | Intrinsically Safe Differential Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C