Fluidwell F119 | Flow rate Indicator / Totalizer with receipt printer driver | linearization, analog and pulse outputs, ambient -40°C to +70°C
The F119 is an advanced flow rate indicator / totalizer with the unique function to send a “print receipt” command to a printer. The configurable ticket printing can be set for (daily) totals or delivery tickets. The F119 provides very precise linearization of the flow meters signal. Typical use: Applications with mechanical flowmeters where a precise calculation over the full measurement range and re-transmission of the flow rate and/or totalizer functions is required.
Key features
- Fifteen point linearization of the flow curve - with interpolation.
- Analog and pulse outputs.
- Large digit selection for flow rate or total.
- Flow rate: seven 17mm (0.67") or 8mm (0.31") digits.
- Total - resettable: seven 17mm (0.67") digits.
- Accumulated total - not resettable: eleven 8mm (0.31") digits.
- Separate engineering units for flow rate and total on the display.
- Specifications
- Features
- Downloads
| Part Number | F119 |
| Brand | Fluidwell |
| Product Type | Flow rate Indicator / Totalizer with receipt printer driver |
| Ambient Temperature | -40 °C to +70 °C (-40 to 158 °F) |
| Signal Inputs - Flowmeter Inputs | Pulse type inputs: Reed-switch, open collector, NAMUR, NPN/PNP pulse, Sine wave (coil), active pulse signal. |
| Supply - Power Supply | Long life Lithium battery.; 4 – 20mA Loop-powered.; Basic: 6 - 30V DC.; 8 - 30V DC + sensor supply. |
| Supply - Sensor Supply | 3.2, 8.2, 12, 24V DC. |
| Signal Inputs - Status Inputs | Remote control: print a ticket, external reset for clearing total or to disable manual clearing by the keypad. |
| Signal Outputs - Pulse Outputs | Function: Scaled pulse output according to linearized accumulated total (e.g. a pulse every 3.25 gallons) or unscaled pulse input retransmission. Max. frequency: 500Hz. Retransmission: Minimum pulse duration: 50µs, square wave output based on frequency of (sine wave or coil) input signal. Adjustable pulse length from 1 msec. Up to 10 seconds.; Type: One passive NPN transistor. |
| Signal Outputs - Analog Outputs | Function: Re-transmitting the linearized flow rate - the output can be scaled to any range (e.g. 200 L/min to 1200 L/min).; Type: One galvanically isolated, loop powered 4 – 20mA output. |
| Hazardous Area - Intrinsically Safe | Not available. |
| Communication | Function: Ticket printing on demand (delivery), ticket printing of daily totals or at contract hour, read and modify all process data and settings. Protocol: Modbus ASCII / RTU. Interface: RS232 or RS485 2-wire. Remote configuration via free downloadable remote configuration tool (see dropdown download above). |
- shows the accumulated total, the current day's total (Daily total), the previous day's total (both non-resettable), the simultaneous linearized flow rate and total, and the totals for 15 prior days.
- The flow curve was linearized at fifteen points using interpolation.
- Pulse and analog outputs.
- Large digit selection available for total or flow rate.
- Seven 17mm (0.67") or 8mm (0.31") numbers indicate the flow rate.
- Total: seven resettable digits measuring 17 mm (0.67").
- Total accumulated: eleven 8mm (0.31") non-resetable digits.
- distinct engineering units on the display for the total and flow rate.
- To print a ticket, reset the total, or lock the "clear total" button, use remote control input.
- LED backlighting.
- Intelligent K-factor arrangement for mass or volumetric flow.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C571 | Flow & Energy Computer | for natural gas, hydrogen and other gases, ambient -40°C to +55/+70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C581 | Flow & Energy Computer | for coolants, water and saturated / superheated steam, ambient -40°C to +70°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell C401 | Hydrogen Dispenser | with metrological approval and receipt printer driver, ambient -25°C to +55°C
Fluidwell F114 | Intrinsically Safe Ratio Monitor / Totalizer | with high / low alarms and analog outputs, ambient -40°C to +70°C
Fluidwell F114 | Intrinsically Safe Ratio Monitor / Totalizer | with high / low alarms and analog outputs, ambient -40°C to +70°C
Fluidwell F116 | Intrinsically Safe Differential / Sum Flow Computer | with Modbus communication, analog and pulse outputs, ambient -40°C to +70°C
Fluidwell F116 | Intrinsically Safe Differential / Sum Flow Computer | with Modbus communication, analog and pulse outputs, ambient -40°C to +70°C
Fluidwell E126-EG | Explosion proof Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EG | Explosion proof Flow Computer for gas | with temperature and pressure compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EL | Explosion proof Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell E126-EL | Explosion proof Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell F127 | Intrinsically Safe Differential Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C
Fluidwell F127 | Intrinsically Safe Differential Flow Computer for liquids | with temperature compensation for corrected volume, ambient -40°C to +70°C