Client Protection
Dedicated Support
Genuine Products
Brannan 10/345/0 | BS 718 M50 Density Hydrometer | 1.35 to 1.40 g/ml, 270 mm
Brannan 10/345/0 reads liquid density between 1.35 and 1.40 g/ml and belongs to the M50 series of BS 718:1991 hydrometers. The 1.35–1.40 g/ml scale of this 270 mm hydrometer is divided in 0.001 g/ml steps, and readings on the 10/345/0 are referenced to 20 °C. Made in the UK, each 10/345/0 arrives in a resealable plastic tube for protection and storage.
Key features
- Reads 1.35 to 1.40 g/ml directly (M50)
- Reads to 0.001 g/ml between 1.35 and 1.40 g/ml, accuracy 0.001 g/ml
- 270 mm M50 body, part 10/345/0
- Medium surface tension class for the M50 1.35–1.40 g/ml range
- 10/345/0 can be supplied with UKAS or traceable certification
If documented calibration is needed, the 10/345/0 can be ordered with a UKAS certificate, a traceable certificate to a recognised national standard, or a Statement of Conformity.
- Specifications
- Features
- Downloads
| Part Number | 10/345/0 |
| Brand | Brannan |
| Standard | BS 718:1991, M50 series |
| Range | 1.35 to 1.40 g/ml |
| Range Span | 0.050 g/ml |
| Divisions | 0.001 g/ml |
| Accuracy | 0.001 g/ml |
| Overall Length | 270 mm |
| Bulb Diameter | 20 to 24 mm |
| Approx. Weight | 42 g (incl. 14 g plastic tube) |
| Material | Soda glass, steel shot ballast, synthetic wax resin |
| Adjusted At | 20 °C |
| Surface Tension | Medium |
| Country of Manufacture | UK |
- 190mm long, Series S50, with range spans of 0.050g/ml and 0.002g/ml
- 270mm long, Series M50, with range spans of 0.050g/ml and 0.001g/ml
- 330mm long, Series L50, with range spans of 0.050g/ml and divisions of 0.0005g/ml
- Produced in the UK and available with a traceable calibration certificate or UKAS
Related Products
Brannan 10/409/0 | BS 718 M100 SP Density Hydrometer | 1.50–1.60 g/ml, 250 mm
Brannan 10/409/0 | BS 718 M100 SP Density Hydrometer | 1.50–1.60 g/ml, 250 mm
Brannan 10/347/0 | BS 718 M50 Density Hydrometer | 1.45 to 1.50 g/ml, 270 mm
Brannan 10/347/0 | BS 718 M50 Density Hydrometer | 1.45 to 1.50 g/ml, 270 mm
Brannan 10/346/0 | BS 718 M50 Density Hydrometer | 1.40 to 1.45 g/ml, 270 mm
Brannan 10/346/0 | BS 718 M50 Density Hydrometer | 1.40 to 1.45 g/ml, 270 mm
Brannan 10/344/0 | BS 718 M50 Density Hydrometer | 1.30 to 1.35 g/ml, 270 mm
Brannan 10/344/0 | BS 718 M50 Density Hydrometer | 1.30 to 1.35 g/ml, 270 mm
Brannan 10/342/0 | BS 718 M50 Density Hydrometer | 1.20 to 1.25 g/ml, 270 mm
Brannan 10/342/0 | BS 718 M50 Density Hydrometer | 1.20 to 1.25 g/ml, 270 mm
Brannan 10/340/0 | BS 718 M50 Density Hydrometer | 1.10 to 1.15 g/ml, 270 mm
Brannan 10/340/0 | BS 718 M50 Density Hydrometer | 1.10 to 1.15 g/ml, 270 mm
Brannan 10/337/0 | Olive Oil Hydrometer | 0.95 to 1.00 g/ml, 270 mm
Brannan 10/337/0 | Olive Oil Hydrometer | 0.95 to 1.00 g/ml, 270 mm