Client Protection
Dedicated Support
Brannan 10/455/0 | BS 718 M50 SP Density Hydrometer | 0.85–0.90 g/ml, 270 mm
Brannan 10/455/0 is the 0.85 to 0.90 g/ml range in the M50 SP density hydrometer series made to BS 718:1991. Reading 0.85–0.90 g/ml in 0.001 g/ml steps, this 270 mm hydrometer is adjusted at 15 °C. The 10/455/0 offers 0.001 g/ml accuracy, tighter than a standard M50 hydrometer, because it belongs to the SP sub-series. The 10/455/0 is intended for low surface tension liquids, and its sub-series corresponds to IP 160 for petroleum testing.
Key features
- Range 0.85 to 0.90 g/ml
- 0.001 g/ml divisions over a 0.050 g/ml span
- 270 mm overall length, 20–24 mm bulb diameter
- Adjusted at 15 °C
- Accuracy 0.001 g/ml, higher than the standard M50 series
- Suitable for low surface tension liquids; corresponds to IP 160
Certification options for the 0.85–0.90 g/ml M50 SP hydrometer from Brannan are UKAS certification, a certificate traceable to a recognised national standard, or a statement of conformity.
- Specifications
- Downloads
| Part Number | 10/455/0 |
| Brand | Brannan |
| Series | M50 SP |
| Standard | BS 718:1991 (generally aligned with ISO 387 and ISO 649) |
| Density Range | 0.85–0.90 g/ml |
| Range Span | 0.050 g/ml |
| Divisions | 0.001 g/ml |
| Accuracy | 0.001 g/ml |
| Overall Length | 270 mm |
| Bulb Diameter | 20–24 mm |
| Approx. Weight | 62 g (incl. 14 g protective tube) |
| Adjustment Temperature | 15 °C |
| Surface Tension | Low |
| Corresponds To | IP 160 |
Related Products
Brannan 10/660/0 | Quevenne Lactometer | 15 to 40 °Quevenne, 160 mm
Brannan 10/660/0 | Quevenne Lactometer | 15 to 40 °Quevenne, 160 mm
Brannan 10/601/0 | Specific Gravity Lactometer | 1.000 to 1.040 SG, 160 mm
Brannan 10/601/0 | Specific Gravity Lactometer | 1.000 to 1.040 SG, 160 mm
Brannan 10/468/5 | BS 718 S60/60F L50 SP Hydrometer | SG 1.00 to 1.05, 335 mm, low surface tension
Brannan 10/468/5 | BS 718 S60/60F L50 SP Hydrometer | SG 1.00 to 1.05, 335 mm, low surface tension
Brannan 10/467/5 | BS 718 S60/60F L50 SP Hydrometer | SG 0.95 to 1.00, 335 mm, low surface tension
Brannan 10/467/5 | BS 718 S60/60F L50 SP Hydrometer | SG 0.95 to 1.00, 335 mm, low surface tension
Brannan 10/469/5 | BS 718 S60/60F L50 SP Hydrometer | SG 1.05 to 1.10, 335 mm, low surface tension
Brannan 10/469/5 | BS 718 S60/60F L50 SP Hydrometer | SG 1.05 to 1.10, 335 mm, low surface tension
Brannan 10/466/5 | BS 718 S60/60F L50 SP Hydrometer | SG 0.90 to 0.95, 335 mm, low surface tension
Brannan 10/466/5 | BS 718 S60/60F L50 SP Hydrometer | SG 0.90 to 0.95, 335 mm, low surface tension
Brannan 10/465/5 | BS 718 S60/60F L50 SP Hydrometer | SG 0.85 to 0.90, 335 mm, low surface tension
Brannan 10/465/5 | BS 718 S60/60F L50 SP Hydrometer | SG 0.85 to 0.90, 335 mm, low surface tension
Brannan 10/464/5 | BS 718 S60/60F L50 SP Hydrometer | SG 0.80 to 0.85, 335 mm, low surface tension
Brannan 10/464/5 | BS 718 S60/60F L50 SP Hydrometer | SG 0.80 to 0.85, 335 mm, low surface tension