Client Protection
Dedicated Support
Brannan 10/882/0 | Specific Gravity Hydrometer, L Series | 1.20 to 1.25 SG, 335 mm
The Brannan 10/882/0 measures specific gravity over a 1.20–1.25 span and belongs to the L series, where every instrument covers 0.050 SG. At 335 mm long and adjusted at 60 °F (15.6 °C), the 10/882/0 is intended for liquids denser than water.
Key features
- 1.20–1.25 SG span (10/882/0)
- 10/882/0: soda glass, steel shot ballast, synthetic wax resin
- Scale referenced to 60 °F / 15.6 °C for the 1.20–1.25 range
- Resolution 0.0005 SG, accuracy ±0.0005 SG (1.20–1.25)
- 335 mm long, stored in a resealable tube (10/882/0)
A UKAS or traceable calibration certificate can be ordered with this 1.20–1.25 SG hydrometer.
- Specifications
- Downloads
| Part Number | 10/882/0 |
| Brand | Brannan |
| Series | L Series |
| Range | 1.20 to 1.25 SG |
| Range Span | 0.050 SG |
| Divisions | 0.0005 SG |
| Accuracy | ±0.0005 SG |
| Adjusted At | 60 °F (15.6 °C) |
| Overall Length | 335 mm |
| Bulb Diameter | 23 to 27 mm |
| Material | Soda glass, steel shot ballast, synthetic wax resin |
| Weight | Approx. 103 g (incl. 47 g plastic tube) |
| Packaging | Protective resealable plastic tube |
| Origin | Made in UK |
Related Products
Brannan 10/468/0 | BS 718 L50 SP Density Hydrometer | 1.00 to 1.05 g/ml, 335 mm, low surface tension
Brannan 10/468/0 | BS 718 L50 SP Density Hydrometer | 1.00 to 1.05 g/ml, 335 mm, low surface tension
Brannan 10/466/0 | BS 718 L50 SP Density Hydrometer | 0.90 to 0.95 g/ml, 335 mm, low surface tension
Brannan 10/466/0 | BS 718 L50 SP Density Hydrometer | 0.90 to 0.95 g/ml, 335 mm, low surface tension
Brannan 10/467/0 | BS 718 L50 SP Density Hydrometer | 0.95 to 1.00 g/ml, 335 mm, low surface tension
Brannan 10/467/0 | BS 718 L50 SP Density Hydrometer | 0.95 to 1.00 g/ml, 335 mm, low surface tension
Brannan 10/465/0 | BS 718 L50 SP Density Hydrometer | 0.85 to 0.90 g/ml, 335 mm, low surface tension
Brannan 10/465/0 | BS 718 L50 SP Density Hydrometer | 0.85 to 0.90 g/ml, 335 mm, low surface tension
Brannan 10/461/0 | BS 718 L50 SP Density Hydrometer | 0.65 to 0.70 g/ml, 335 mm, low surface tension
Brannan 10/461/0 | BS 718 L50 SP Density Hydrometer | 0.65 to 0.70 g/ml, 335 mm, low surface tension
Brannan 10/462/0 | BS 718 L50 SP Density Hydrometer | 0.70 to 0.75 g/ml, 335 mm, low surface tension
Brannan 10/462/0 | BS 718 L50 SP Density Hydrometer | 0.70 to 0.75 g/ml, 335 mm, low surface tension
Brannan 10/469/0 | BS 718 L50 SP Density Hydrometer | 1.05 to 1.10 g/ml, 335 mm, low surface tension
Brannan 10/469/0 | BS 718 L50 SP Density Hydrometer | 1.05 to 1.10 g/ml, 335 mm, low surface tension
Brannan 10/460/0 | BS 718 L50 SP Density Hydrometer | 0.60 to 0.65 g/ml, 335 mm, low surface tension
Brannan 10/460/0 | BS 718 L50 SP Density Hydrometer | 0.60 to 0.65 g/ml, 335 mm, low surface tension