Client Protection
Dedicated Support
Desoutter DRT 5 Sq 5000 | Digital Rotary Torque & Angle Transducer | 500-5000 Nm, 1-1/2 in Sq Drive, 1000 rpm
The Desoutter DRT 5 Sq 5000 (part number 6151657800) is a digital rotary transducer that measures torque and angle from 500 Nm (369 ft.lbf) up to 5000 Nm (3690 ft.lbf), with a 1-1/2 in square output drive and a maximum free speed of 1000 rpm. With a Delta 6 or 7D, the DRT 5 Sq 5000 checks tightening tools for quality control.
Key features
- Measures torque and angle on the DRT 5 Sq 5000 with ±0.35% of FSD accuracy
- The DRT 5 Sq 5000 withstands an overload torque of 6250 Nm (4610 ft.lbf)
- Smart memory chip lets the Delta recognise the DRT 5 Sq 5000 automatically, avoiding setting errors
- Digital signal from the DRT 5 Sq 5000 gives fast data transfer free of external noise
- Torque and angle curves from the DRT 5 Sq 5000 support detailed joint analysis
- Specifications
- Downloads
| Part Number | 6151657800 |
| Model | DRT 5 Sq 5000 |
| Brand | Desoutter |
| Measurand | Torque & Angle |
| Min Torque capacity | 500 Nm (369 ft.lbf) |
| Max Torque capacity | 5000 Nm (3690 ft.lbf) |
| Overload torque | 6250 Nm (4610 ft.lbf) |
| Output drive size (in) | 1-1/2 |
| Output drive type | Sq |
| Max free speed | 1000 rpm |
| Accuracy | ±0.35% of FSD |
| Signal Type | Digital |
| Transducer Type | Rotary |
| Weight | 5.1 kg (11.2 lb) |
Related Products
SAUTER DC 100-Y1 | Static Torque Sensor | 0.5% F.S. Error, 1.9 mV/V
SAUTER DC 100-Y1 | Static Torque Sensor | 0.5% F.S. Error, 1.9 mV/V
SAUTER DC 10-Y2 | Static Torque Sensor DC 10-Y2 | 0.5% Combined Error, IP65
SAUTER DC 10-Y2 | Static Torque Sensor DC 10-Y2 | 0.5% Combined Error, IP65
SAUTER DC 10-Y1 | Static Torque Sensor DC 10-Y1 | 0.5% Combined Error, 1.2 mV/V
SAUTER DC 10-Y1 | Static Torque Sensor DC 10-Y1 | 0.5% Combined Error, 1.2 mV/V
SAUTER DC 200-Y1 | Static Torque Sensor DC 200-Y1 | Alloy Steel, 0.5 % Combined Error
SAUTER DC 200-Y1 | Static Torque Sensor DC 200-Y1 | Alloy Steel, 0.5 % Combined Error
SAUTER DC 20-Y1 | Static Torque Sensor | 0.5% Combined Error, 1.3 mV/V
SAUTER DC 20-Y1 | Static Torque Sensor | 0.5% Combined Error, 1.3 mV/V
SAUTER DC 20-Y2 | Static Torque Sensor | 0.5% Combined Error, IP65
SAUTER DC 20-Y2 | Static Torque Sensor | 0.5% Combined Error, IP65
SAUTER DC 200M-Y2 | Static Torque Sensor DC 200M-Y2 | Alloy Steel, 0.5% F.S., IP65
SAUTER DC 200M-Y2 | Static Torque Sensor DC 200M-Y2 | Alloy Steel, 0.5% F.S., IP65
SAUTER DC 5-Y1 | Static Torque Sensor | Alloy Steel, 1.5 mV/V
SAUTER DC 5-Y1 | Static Torque Sensor | Alloy Steel, 1.5 mV/V