Dwyer 673-2 | Pressure Transmitter | 0 to 2 psi, ± 0.25 %, 4 to 20 mA
The Dwyer 673-2 is a pressure transmitter: range 0-2 psi.
The Dwyer Series 673 is a fixed-range pressure transmitter designed for harsh environments and suitable for high shock and vibration applications. The series provides a 4-20 mA output signal with ±0.25% accuracy, intended for use in industrial OEM equipment, hydraulic systems, HVAC equipment, industrial engines, and compressor controls. The Series 673 measures pressure from compatible liquid, gas, or vapor services using wetted materials of 17-4 PH stainless steel.
- Accuracy: ± 0.25 %
- Accuracy Detail: ± 0.25% BFSL (RSS), (includes non-linearity, hysteresis and nonrepeatability)
- Compensated Temperature, Max: 176 °F
- Compensated Temperature, Min: -40 °F
- Electrical Connection: Cable
- Electrical Output: 4 to 20 mA
- Specifications
- Features
- Downloads
| Part Number | 673-2 |
| Brand | Dwyer |
| Series | 673 |
| Accuracy | ± 0.25 % |
| Electrical Connection | Cable |
| Supply Voltage | 9 to 30 Vdc |
| Weight | 65 g |
| Accuracy Detail | ± 0.25% BFSL (RSS), (includes non-linearity, hysteresis and nonrepeatability) |
| Compensated Temperature, Max | 176 °F |
| Compensated Temperature, Min | -40 °F |
| Electrical Output | 4 to 20 mA |
| Loop Resistance | < 800 Ω |
| Materials | Stainless Steel, Valox |
| Measurement Pressure Type | Gauge |
| Measurement Pressure, Max | 2 psi |
| Measurement Pressure, Min | 0 psi |
| Number of Wires | 2 |
| Operating Temperature, Max | 185 °F |
| Operating Temperature, Min | -40 °F |
| Output Detail | 4 to 20 mA |
| Output Signal | 4 to 20 mA |
| Proof Pressure | Up to 2000 psi |
| Response Time | 5 ms |
| Shock | 200 g |
| Span Adjustment | Fixed |
| Stability | 0.5% FS/year |
| Supply Power Type | DC |
| Thermal Effects | Zero: ± 3.6% FS/100 °F; Span: ± 2.7% FS/100 °F |
| Vibration | 20 g |
| Zero Setting Adjustable Range | Fixed |
| Country of Origin | United States |
- Accuracy: ± 0.25 %
- Accuracy Detail: ± 0.25% BFSL (RSS), (includes non-linearity, hysteresis and nonrepeatability)
- Compensated Temperature, Max: 176 °F
- Compensated Temperature, Min: -40 °F
- Electrical Connection: Cable
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer Series FDT | Flush Diaphragm Pressure Transmitter
Dwyer Series FDT | Flush Diaphragm Pressure Transmitter
Dwyer 636-2 | Fixed Range Pressure Transmitter | 0 to 100 psi, ± 0.3 %, 4 to 20 mA
Dwyer 636-2 | Fixed Range Pressure Transmitter | 0 to 100 psi, ± 0.3 %, 4 to 20 mA
Dwyer 636-7 | Fixed Range Pressure Transmitter | 0 to 60 psi, ± 0.3 %, 4 to 20 mA
Dwyer 636-7 | Fixed Range Pressure Transmitter | 0 to 60 psi, ± 0.3 %, 4 to 20 mA
Dwyer 636-4 | Fixed Range Pressure Transmitter | 0 to 1000 psi, ± 0.3 %, 4 to 20 mA
Dwyer 636-4 | Fixed Range Pressure Transmitter | 0 to 1000 psi, ± 0.3 %, 4 to 20 mA
Dwyer 636-3 | Fixed Range Pressure Transmitter | 0 to 300 psi, ± 0.3 %, 4 to 20 mA
Dwyer 636-3 | Fixed Range Pressure Transmitter | 0 to 300 psi, ± 0.3 %, 4 to 20 mA
Dwyer 636-6 | Fixed Range Pressure Transmitter | 0 to 5000 psi, ± 0.3 %, 4 to 20 mA
Dwyer 636-6 | Fixed Range Pressure Transmitter | 0 to 5000 psi, ± 0.3 %, 4 to 20 mA
Dwyer 3200G-4-FM-1-1-LCD | Explosion-proof Pressure Transmitter | 0 to 3600 psi, ± 0.075 %, 4 to 20 mA
Dwyer 3200G-4-FM-1-1-LCD | Explosion-proof Pressure Transmitter | 0 to 3600 psi, ± 0.075 %, 4 to 20 mA
Dwyer 636-1 | Fixed Range Pressure Transmitter | 0 to 30 psi, ± 0.3 %, 4 to 20 mA
Dwyer 636-1 | Fixed Range Pressure Transmitter | 0 to 30 psi, ± 0.3 %, 4 to 20 mA