Dwyer Instruments CDTR-2E404 | Carbon Dioxide/Humidity | Wall Mount | Universal current/voltage output | European Housing
The number of sensors installed on a wall or in a duct is decreased with the Carbon Dioxide, Relative Humidity, and Temperature Transmitters, Series CDTR, Model CDTR-2E404. System integrators can cut installation time and material costs by integrating temperature, RH, and CO2 into a single device. A single beam dual wavelength non-dispersive infrared (NDIR) sensor is employed, similar to our well-liked Series CDT Carbon Dioxide Transmitter, to automatically correct the measurement against light source aging effects in both occupied* and unoccupied buildings. The Series CDTR also has the capability to field calibrate the sensor and adjust digitally for barometric pressure, ensuring optimal accuracy. Users can choose the transmitter output to be 4 to 20 mA, 0 to 5 VDC, or 0 to 10 VDC to work with almost any building management controller thanks to universal outputs for both carbon dioxide and relative humidity. For a temperature output, an RTD sensor or passive thermistor can also be supplied. The Series CDTR wall mount versions can be supplied with an integrated LCD display for applications that need visual indication. Temperature only, relative humidity only, CO2 only, CO2 and humidity, or CO2 and temperature are the possible configurations for the display. All transmitter variants come with push buttons that allow users to access the menu structure. An internal jumper option can be used to lock out button operation to avoid tampering.

Free UAE shipping available
- Specifications
- Features
- Downloads
Accuracy | +/-40 PPM + 3% of reading (CO2) +/-2% (RH) |
Approvals | CE |
Enclosure Rating | Duct mount: NEMA 4X (IP66) for housing only Wall mount: IP20 |
Humidity | Limits: 10 to 95% RH (non-condensing) |
Manufacturer | Dwyer Instruments |
Maximum operating temperature | 32 to 122°F (0 to 50°C) |
Non Linearity | 16 PPM |
Output | Current: 4 to 20 mA (max 500 ¢ž¦) Voltage: 0 to 5 VDC or 0 to 10 VDC (min 500 ¢ž¦) Relay: SPST NO 2A @ 30 VDC RTD or thermistor per r-t curves (depending on model) |
POWER CONSUMPTION | Average: 2 watts Peak: 3.75 watts |
Power | 16 to 35 VDC / 19 to 28 VAC |
PRESSURE | Dependence: 0.13% of reading per mm of Hg |
Range | CO2: 0 to 2000 or 0 to 5000 PPM (depending on model) Relative humidity: 0 to 100% Temperature: 32 to 122°F (0 to 50°C) |
Range | Duct Air Velocity: 0-4000 FPM (20.32 m/s) |
Response Time | 2 minutes for 99% step change |
Sensor Type | Single-beam, dual-wavelength NDIR |
Temperature | Dependence: +/-8 ppm/ °C at 1100 PPM |
Type | Carbon Dioxide, Relative Humidity and Temperature Transmitters |
Weight | 5.6 oz (158.8 g) |
- The self-heating effects of wall mount combination devices are eliminated by the Digital Intelligence Temperature Compensation Algorithm (DITCATM).
- Dual wavelength, one beam NDIR CO2 sensor.
- Interchangeable temperature and humidity sensors.
- Hardware lockout on a physical level.
- For wall mount and duct mount units without an LCD relay output option, there is a service display tool available.
Related Products

Dwyer Instruments CMS300-FC | Carbon monoxide transmitter & switch | 0-300 PPM | 4-20 mA/2-10 V (maximum load 2K Ω) | Includes factory calibration certificate

Dwyer Instruments CMS300-FC | Carbon monoxide transmitter & switch | 0-300 PPM | 4-20 mA/2-10 V (maximum load 2K Ω) | Includes factory calibration certificate

Dwyer Instruments CMS300 | Carbon monoxide transmitter & switch | 0-300 PPM | 4-20 mA/2-10 V (maximum load 2K Ω)

Dwyer Instruments CMS300 | Carbon monoxide transmitter & switch | 0-300 PPM | 4-20 mA/2-10 V (maximum load 2K Ω)

Dwyer Instruments GSTC-N-LCD-FC | Nitrogen Dioxide duct mount transmitter with BACnet & Modbus® communication | LCD display | Includes factory calibration certificate

Dwyer Instruments GSTC-N-LCD-FC | Nitrogen Dioxide duct mount transmitter with BACnet & Modbus® communication | LCD display | Includes factory calibration certificate

Dwyer Instruments GSTC-N-LCD | Nitrogen Dioxide Transmitter with BACnet & Modbus Communication with Integral LCD Display

Dwyer Instruments GSTC-N-LCD | Nitrogen Dioxide Transmitter with BACnet & Modbus Communication with Integral LCD Display

Dwyer Instruments GSTC-N-FC | Nitrogen Dioxide transmitter with BACnet & Modbus® communication | Includes factory calibration certificate

Dwyer Instruments GSTC-N-FC | Nitrogen Dioxide transmitter with BACnet & Modbus® communication | Includes factory calibration certificate

Dwyer Instruments GSTC-N-D-FC | Nitrogen Dioxide duct mount transmitter with BACnet & Modbus® communication | Includes factory calibration certificate

Dwyer Instruments GSTC-N-D-FC | Nitrogen Dioxide duct mount transmitter with BACnet & Modbus® communication | Includes factory calibration certificate

Dwyer Instruments GSTC-N-D | Nitrogen Dioxide Duct Mount Transmitter with BACnet & Modbus Communication

Dwyer Instruments GSTC-N-D | Nitrogen Dioxide Duct Mount Transmitter with BACnet & Modbus Communication

Dwyer Instruments GSTC-N | Nitrogen Dioxide Transmitter with BACnet & Modbus Communication

Dwyer Instruments GSTC-N | Nitrogen Dioxide Transmitter with BACnet & Modbus Communication