Dwyer CDTV-2D4E4 | Carbon Dioxide Transmitter
The Dwyer CDTV-2D4E4 is a carbon dioxide transmitter with accuracy CO₂: ±40 ppm + 3% of reading, approvals CE and enclosure rating NEMA 4X (IP66), housing only. Dwyer lists combination CO2 and VOC outputs lower material and labor costs., single beam dual wavelength NDIR CO2 sensor allows for usage in locations that may be used 24 hours a day. and there is a correlation between VOC emission and CO2 measurements. among its features.
- Accuracy: CO₂: ±40 ppm + 3% of reading
- Approvals: CE
- Enclosure Rating: NEMA 4X (IP66), housing only
- Maximum Operating Temperature: 32 to 122°F (0 to 50°C)
- Mounting: Duct mount
- Non-Linearity: CO₂: 16 ppm
- POWER CONSUMPTION: Average: 2 W Peak: 3.75 W
- Power: 16-35 VDC or 19-28 VAC
- Specifications
- Features
- Downloads
| Part Number | CDTV-2D4E4 |
| Type | Carbon Dioxide/Volatile Organic Compound Transmitter |
| Accuracy | CO₂: ±40 ppm + 3% of reading |
| Output | Current: 0-20 mA, 4-20 mA, 0-10 mA, or 2-10 mA (jumper selectable, max 500 Ω) Voltage: 0-10 VDC, 2-10 VDC, 0-5 VDC, or 1-5 VDC (jumper selectable, min 500 Ω) |
| Range | CO₂: 0-2000 PPM VOC: 0-2000 ppm CO₂ equivalent |
| Range | Duct Air Velocity: 0-4000 FPM (20.32 m/s) |
| Response Time | CO₂: 2 minutes for 99% step change; VOC: 5 minutes |
| Approvals | CE |
| Maximum Operating Temperature | 32 to 122 °F (0 to 50 °C) |
| Power | 16-35 VDC or 19-28 VAC |
| Sensor Type | CO₂: Single-beam, dual-wavelength NDIR; VOC: MEMS metal oxide semiconductor |
| Display | None |
| Mounting | Duct mount |
| Enclosure Rating | NEMA 4X (IP66), housing only |
| Weight | 5.6 oz (158.8 g) |
| Power Consumption | Average: 2 W Peak: 3.75 W |
| Manufacturer | Dwyer Instruments |
| Non-Linearity | CO₂: 16 ppm |
| Pressure | Dependence: CO₂: 0.13% of reading per mm Hg |
| Temperature | Dependence: ±8 ppm/°C at 1100 ppm |
| Temperature Sensor | Pt1000 Ω RTD |
| Temperature Limits | 32 to 122 °F (0 to 50 °C) |
- Combination CO2 and VOC outputs lower material and labor costs.
- Single beam dual wavelength NDIR CO2 sensor allows for usage in locations that may be used 24 hours a day.
- There is a correlation between VOC emission and CO2 measurements.
- Utilize ASHRE's occupancy-based VRP Algorithm for ventilation.
Other models in this series
Click a row to open that product.
Highlighted values differ from the model you are viewing.
Related Products
Dwyer CMS300-FC | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer CMS300-FC | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer CMS300 | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer CMS300 | Carbon Dioxide Transmitter | 0-300 PPM, 4 to 122°F (-20 to 50°C)
Dwyer GSTC-N-LCD-FC | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-LCD-FC | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-LCD | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-LCD | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-FC | Nitrogen Dioxide Transmitter | BACnet & Modbus®, Factory Calibration Certificate
Dwyer GSTC-N-FC | Nitrogen Dioxide Transmitter | BACnet & Modbus®, Factory Calibration Certificate
Dwyer GSTC-N-D-FC | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-D-FC | Carbon Dioxide Transmitter | Drift: <5% per year in air, CO: 1 PPM; NO₂: 0.1 PPM
Dwyer GSTC-N-D | Nitrogen Dioxide Duct Transmitter | 0-10 ppm NO2, BACnet/Modbus
Dwyer GSTC-N-D | Nitrogen Dioxide Duct Transmitter | 0-10 ppm NO2, BACnet/Modbus
Dwyer GSTC-N | Carbon Dioxide Transmitter | CO: 0 to 500 PPM NO₂: 10 PPM, Drift: <5% per year in air
Dwyer GSTC-N | Carbon Dioxide Transmitter | CO: 0 to 500 PPM NO₂: 10 PPM, Drift: <5% per year in air