Norbar 43219 | Torque Calibrator | 1 in 9999, 8 - 400 N.m
The Norbar 43219 is a torque calibrator with accuracy BS7882:2017 Class 1, ±0.5% of reading, female drive 1/2" & 3/4" and maximum resolution 1 in 9999. Norbar lists high measurement accuracy: BS 7882:2017 Class 1 accuracy of ±0.5% of reading over the primary range., wide torque coverage: Measures from 8 to 400 N·m. and dual drive compatibility: Includes 1/2" and 3/4" female drive options. among its features.
- Female Drive: 1/2" & 3/4"
- Maximum Resolution: 1 in 9999
- Model Number: Pro-Test 400
- Operational Range: 8 - 400 N.m
- Product Number: 43219
- Range Imperial: 6 - 295 lbf·ft
- Range Metric: 8 - 400 N·m
- Temp Range - Operating: 5°C to 40°C
- Specifications
- Features
- Downloads
| Brand | Norbar |
| Model Number | Pro-Test 400 |
| Product Number | 43219 |
| Range Imperial | 6 - 295 lbf·ft |
| Range Metric | 8 - 400 N·m |
| Accuracy | BS7882:2017 Class 1, ±0.5% of reading |
| Modes | Track, Peak, First Peak |
| Calibration | UKAS certificate, clockwise |
| Female Drive | 1/2" & 3/4" |
| Maximum Resolution | 1 in 9999 |
| Operational Range | 8 - 400 N.m |
| Temp Range - Operating | 5 °C to 40 °C (41 to 104 °F) |
| Temp Range - Storage | 20 °C to +70 °C (68 to 158 °F) |
| Transducer Overload Capacity | 150% of Calibration |
| Weight | 6.4 Kg |
| Interface | RS-232-C |
| Origin | Made in the UK |
Three essential operating modes allow the Pro-Test to be used with all torque wrench types: 'Track' displays the live value, 'Peak Memory' records the highest value and 'First Peak Memory' records the first peak of torque (for click type torque wrenches). Both memory modes can be used with manual or automatic reset.
Large back lit display is easily visible from a distance and in poor light.
All common units of torque measurement are included.
User can select the language they wish to work in (most European languages are included).
Transducer can be mounted for torque wrench operation in the horizontal or vertical plane.
RS-232-C is included for the output of reading to a printer, PC, data capture unit, SPC software etc.
Optional mounting plate, Part Code 62198, allows the Pro-Test to be wall mounted.
All user settable parameters are menu selectable from the front panel.
As standard, all transducers are calibrated in a clockwise direction. For additional anti clockwise direction order Part No. PROTEST.CCW.
Display and Transducer are hard-wired together with a 600mm cable.
Pictorial 'Mode' selection incorporated for ease of use.
Supplied in a robust plastic case with a data transfer lead to connect to a PC or printer.
Guaranteed classification to BS7882:2017, Class 1 or better over the primary calibration range (20% to 100% of full scale), Class 2 or better over the secondary calibration range (lowest calibrated value to 20% of full scale). Class 1 equates to ±0.5% of reading
Other models in this series
Click a row to open that product.
Related Products
Norbar 80025 | Intervention Tool Test Pot ISO 13628-8 Class 6
Norbar 80025 | Intervention Tool Test Pot ISO 13628-8 Class 6
Norbar 80020 | Intervention Tool Test Pot API 17D Class 7
Norbar 80020 | Intervention Tool Test Pot API 17D Class 7
Norbar 21429 | Torque Transducer Calibration Beam 60 N·m
Norbar 21429 | Torque Transducer Calibration Beam 60 N·m
Norbar 21421 | Torque Transducer Calibration Beam 150 N·m
Norbar 21421 | Torque Transducer Calibration Beam 150 N·m
Norbar 21427 | Torque Transducer Calibration Beam 500 N·m
Norbar 21427 | Torque Transducer Calibration Beam 500 N·m
Norbar 21400 | Torque Transducer Calibration Beam 3 N·m
Norbar 21400 | Torque Transducer Calibration Beam 3 N·m
Norbar 21430 | Torque Transducer Calibration Beam 500 lbf·in
Norbar 21430 | Torque Transducer Calibration Beam 500 lbf·in
Norbar 21428 | Torque Transducer Calibration Beam 1,500 N·m
Norbar 21428 | Torque Transducer Calibration Beam 1,500 N·m